Stiebel Eltron Solar Controller - SOM 10 - 36000667
- 14 Input Sensors and Vbus Connection - 4 Output semiconductor relays
Product ID • 360006670000
Available in Stock: 0
- This Product is no longer available through Houseneeds.com. It has either been discontinued, made obsolete, or is no longer available for sale. Please select another product.
Overview
The Stiebel Eltron SOM 10 series solar thermal controllers are multi-funtional temperature differential controllers that provide complete control of the solar thermal system for safe and long-lasting operation. The SOM 10 has up to 14 Relay Outputs for sensors and controls thermal solar energy by means of a collector sensor and a storage tank sensor. The SOM 10 series controllers also implements important system monitoring and safety functions. The system parameters and measured values can be viewed and altered by the large LCD display. Semiconductor relay for pump speed control.
The Stiebel Eltron SOM 10 controller is equipped with 14 temperature sensor outputs and 4 inputs.
Manuals & Docs
Technical Specs
Stiebel Eltron Solar Controller - SOM 10 - 36000667 Techs and Specs
- Sensor Outputs
- 14
- Sensor Inputs
- 4
- Speed Control Triac Output (30 to 100%)
- 2
- Drainback pump peed control
- Yes
- Collector freeze protection
- Yes
- Evacuated tube collector function
- Yes
- Min collector temperature
- Yes
- Collector cooling functions
- Yes
- Tank (nighttime) cooling
- Yes
- Emergency shutdown functions
- Yes
- Operating hours counter
- Yes
- Energy metering measurement
- Yes
- Vbus data commincation
- Yes
Stiebel Eltron Solar Controller SOM 10 - 36000667 Features
- Delta T Controller - When the switch-on difference is reached, the pump is activated until the differential temperature drops below
- Maximum tank temperature - When the adjusted maximum tank temperature is exceeded, the pump switches off
- Collector emergency shutdown - If adjusted collector temperature is exceeded, the solar pump is switched off
- System cooling - If the temperature rises to the maximum collector temperature the solar pump remains on until the temperature drops
- Minimum collector temperature - a minimum set temperature which must be exceeded before the solar pump is switched-on
- Antifreeze function - If the adjusted temperature drops, the solar pump is switched on to protect the fluid from freezing
- Tank Cooling Function - In the evening, the solar pump continues running until the storage tank is cooled down
- Tube Collector Function - The controller measures an increase of heat rise in the collector and adjusts operation for maximum efficiency
- Heat Generation Measrurement KWh (BTu)- The heat generated is measured by the flow and the temperature of feed and return sensors
- Operating hours counter - Operating hours counter stores the solar operating hours of the respective relay
- Manual operating mode - For control and servicing, the operating mode of the controller can be switched manually