IBC Super Flow Dual Fired Condensing Combi Boiler - SFC 125
- Natural Gas or Propane Gas - Built in Domestic Water - 99000 Btus - 125000 Btus
Product ID • IBCSFC125000
Overview
IBC Super Flow Dual Fired Condensing Combi Boiler - NG/LP - 99 MBH / 125 MBH - SFC 125
A dual fired combi boiler - the SFC provides not only high-efficiency space heating, but unrivaled domestic hot water efficiency too. We call this ‘Double HE’. The secret lies in our patented two-in-one heat exchanger that ensures optimal heat transfer and minimal heat loss. The SFC 125 will produce 99,000 Btu's for Heating and 125,000 Btu's for Domestic Hot Water automatically.
Flue gases are condensed with both space heating and domestic hot water production ensuring heat extraction to the fullest extent possible.
The IBC SFC 125 assures you unrivaled high-efficiency and economical operation year in, year out.
This IBC Natural Gas or Propane Gas Combination Boiler SFC 125 is a very high efficiency dual purpose Wall Hung Boiler with an AFUE rating of 95%. The IBCCombination Boiler provides 99K BTUs for space heating with Domestic Hot Water Capability of 125,000 that can provide 3.2 gal/minute at a 77 degrees or 3.2 Gallons at a 70 degree temperature rise. This IBC Residential Combi Boiler provides home owners with one appliance that saves money on operating expenses, reduces overall installation costs and takes up less space than traditional space heating and water heating appliances..
Manuals & Docs
Technical Specs
IBC Wall Hung Combination Boiler SFC 125 Techs and Specs
- Gas
- Natural Gas
- Maximum Heat Input
- 99,000 Btu/hr
- Minimum heat input
- 16,500 Btu/hr
- Maximum DWH Input
- 125,000 Btu/hr
- Minimum DWH input
- 16,500 Btu/hr
- Efficiency
- 95%
- D.H.W. Minimum Flow Rate
- 0.5 GPM
- Domestic Hot Water Flow - 45 Degree Rise
- 4.2 GPM
- Domestic Hot Water Flow - 70 Degree Rise
- 3.2 GPM
- Nominal power supply voltage
- 120/60 V/Hz
- Dimensions
- 17.7 Inches L x 32.5 Inches H x 11.2 Inches D
- Venting Size 2 Inches
- 35 Foot Max less elbows
- Domestic Water Pipe Connections
- 1/2 Inch NPT
- Heating Water Pipe Connections
- 3/4 Inch NPT
- Gas Pipe Connections
- 1/2 Inch NPT
- Venting Size 2 Inches
- 35 Foot Max less elbows
- Venting Size 3 Inches
- 120 Foot Max less elbows
- Maximum heating pressure
- 30 Psi
- Maximum pressure of domestic water circuit
- 150 Psi
- Weight
- 85 Pounds
IBC Wall Hung Combination Boiler SFC 125 Features
- With On-Demand Hot Water - Combi - Wall Mounted
- Patented ASME "H" heat exchanger
- Certified DOE efficiency of 95% Efficiency
- Reverse Coil potable domestic hot water supply
- Integral system circulator
- Expansion tank and air vent
- Natural Gas or Propane Gas
- Can be vented with PVC or CPVC