Tamarack TC1000H House Fans - Techs & Specs
|
Tamarack TC1000H Specifications
|
|
TC1000-H
|
|
Power Requirement
|
115VAC 60Hz
|
|
Fan Running High
|
110 watts 1.5 amps
|
|
Fan Running Low
|
50 watts .73 amps
|
|
Lift Motor Running
|
6 watts
|
|
Open/Close Time
|
30 seconds
|
|
High Air Flow
|
800 cfm
|
|
Low Air Flow
|
500 cfm
|
|
R Value Through Insulation
|
R 6 / Insulated Damper
|
|
Rough Opening
|
12.5" x 27"
|
|
Flange
|
16.875" x 36" x .25"
|
|
Cover Height Above Flange
|
5"
|
|
Box Depth Below Flange
|
2.5"
|
|
Htg Deflection Temperature
|
180°F
|
|
Color
|
White
|
|
Weight
|
16 pounds
|
|
Note: This product requires Single Throw Wall Switch
|
|
Tamarack TC1000H House Fan Dimensions
- 36"
- 16.875"
- .250"
|
Installation Tips for the TC1000-H
When the fan is installed in a solid roof, it should be installed with a 1/4" thick flange
and a "thimble" or "chase" - a piece of metal that is pushed up into the unit from the
room side. The thimble finishes the air passage from the living space to the fan and protects
the insulation from any moisture.
If the fan is mounted in a wall system, some extra attention should be paid to weeping the
water over the hood of the fan. This can be done by the addition of an extra piece of flashing
or a room overhang.
When the fan is installed in a glazing system, the flange size should match the glass size.
If the glass is 7/8" thick, for example, the flange can be made 7/8" to match.
|
|
|