Tamarack Techs and Specs - MainStream Whole House Fan
|
The Mainstream system includes the following items:
- Mainstream fan
- Electrical box cover/grille bracket
- Grille
- Thumbscrew
Note: The Mainstream-MHV will include an Airetrak
|
|
Installation:
- Remove the existing fan. Set the screws aside
- Ensure that the roof cap is unobstructed
- On the Mainstream, remove the electrical box cover/grille bracket by removing the two screws on the fan housing. Set the screws aside
- Slide in the Mainstream, making sure that the source electrical wires are fed into the electrical box and that the romex clamp is tightened
- Using the screws from the original fan and the existing hole locations, attach the Mainstream to the ceiling through the plastic flange
- Make the electrical connections as shown the the wiring diagram
- Re-install the electrical box cover/grille bracket
- Attach the grille with the thumbscrew
|
|
Wiring:
State and local electrical code may require that these devices
be installed by a licensed electrician. Check with your
code officials before installing.
|
|
Specifications
|
|
Model Mainstream™
|
Model Mainstream™-MHV
|
|
Power Requirement
|
115 VAC .3 Amps
|
115 VAC (Amps vary with Airetrak setting)
|
|
Fan Running
|
19 watts
|
18 watts (low)
30 watts (high)
|
|
Air Flow
|
96 cfm @ .1" wg
|
45 cfm @ .1" wg (low)
96 cfm @ .1" wg (high)
|
|
Sound Level
|
1.5 sones
|
.5 sones (low)
2 sones (high)
|
|
Duct Connection
|
7 inches
|
|
Interior Grille
|
11 inches x 11 inches x 2 inches
|
|
Grille Color
|
White
|
|
Weight
|
5 lbs. (shipping 7 lbs.)
|
|
|