Fantech Energy Recovery Ventilator - Techs and Specs
Install Manuals at the bottom of this page
|
SER Energy Recovery Ventilator Specifications
|
House in Square Feet*
|
Up to 3200 sq. ft.**
|
Up to 4200 sq. ft.
|
|
Model Number
|
SER 1504
|
SER 1504N
|
SER 2004
|
SER 2004N
|
|
Port Location (size)
|
Side - 6 inch
|
Side - 6 inch
|
Side - 6 inch
|
Side - 6 inch
|
|
Average Installed Range of Air Flow
|
50-130 CFM
|
50-130 CFM
|
60-170 CFM
|
60-170 CFM
|
|
Defrost Cycle Strategy
|
Continuous Exhaust
|
none
|
Continuous Exhaust
|
none
|
|
Control Options
|
Low voltage
|
Low voltage
|
Low voltage
|
Low voltage
|
|
Dimensions (inches)
|
23 1/2 L x 17 3/8 W x 16 1/8 H
|
23 1/2 L x 17 3/8 W x 16 1/8 H
|
27 7/8 L x 17 3/8 W x 20 1/2 H
|
27 7/8 L x 17 3/8 W x 20 1/2 H
|
|
Effectiveness (ASE) at 32°F
|
58
|
58
|
66
|
66
|
|
Total Recovery Efficiency (TRE) at 95°F
|
49
|
49
|
57
|
57
|
* Total square footage of home plus basement with 8' ceilings estimated at 1 Air Change Per
Every 3 Hours. Use for rough sizing only.
** Can be used in larger homes for low level background ventilation, if bathrooms have separate
dedicated exhaust fans.
|
|
|
Fantech Energy Recovery Ventilator SER Measurements
|
|
Model
|
SER 1504N
|
SER 2004N
|
|
A
|
2 1/4 inches
|
2 1/4 inches
|
|
B
|
23 1/2 inches
|
27 7/8 inches
|
|
C
|
2 5/8 inches
|
2 5/8 inches
|
|
D
|
17 3/8 inches
|
17 3/8 inches
|
|
E
|
16 1/8 inches
|
20 1/2 inches
|
|
F
|
6 inches
|
6 inches
|
|