Description
|
BMS 10/20
|
|
Rated Heat Input (btu/h)
|
87,000
|
|
Rated Heat Output (btu/h)
|
73,000
|
|
Rated Efficiency
|
86%
|
|
Concentric Vent Pipe Size
|
4 inches
|
|
Concentric Vent Pipe Max Length
|
5 Meters (15 Feet) with no elbows - and subtract 1 Meter for each Elbow
|
|
Max Pressure on Heating Circuit
|
30 PSI
|
|
Water Temp in Heating Circuit
|
90-degrees to 180-degrees
|
|
Domestic Hot Water
|
90-degrees to 180-degrees
Note: You must use a Anti-Scald Mixing Valve!
|
Domestic Hot Water Output
60-Degrees Rise
|
2.65 gpm
|
|
Minimum Domestic Hot Water Flow
|
N/A
|
|
Gas Connection
|
3/4 Inch
|
|
Hot/Cold Water Connections
|
3/4 Inch
|
|
Dimensions
|
H 35" by W 18" by D 15"
|
|
Weight
|
143 Pounds
|
|
Voltage
|
120 volts
|
Please Note:
The Massachusetts approval code is 03-05070014.
The Massachusetts MEA numbers are: BMS - G3 - 1003 - 46
The New York MEA numbers are: BMS - 389 - 99 - M
This Gas boiler is not approved in Michigan.
|