Axia Gas Boiler Description
|
AXIA 20E
|
AXIA 29E
|
|
Rated Heat Input (btu/h)
|
90,000
|
160,000
|
|
Rated Heat Output (btu/h)
|
76,500
|
136,000
|
|
Reduced Heat Input (btu/h)
|
50,000
|
90,000
|
|
Reduced Heat Output (btu/h)
|
42,500
|
76,500
|
|
Rated Efficiency
|
86%
|
|
Concentric Vent Pipe Size
|
4 inches
|
|
Concentric Vent Pipe Max Length
|
5 Meters (15 Feet) with no elbows - and subtract 1 Meter for each Elbow
|
|
Max Pressure on Heating Circuit
|
30 PSI
|
|
Water Temp in Heating Circuit
|
90-degrees to 180-degrees
|
|
Domestic Hot Water
|
90-degrees to 180-degrees
Note: You must use a Anti-Scald Mixing Valve!
|
Domestic Hot Water Output
60-Degrees Rise
|
2.6 gpm
|
4.6 gpm
|
Domestic Hot Water Output
Intermittent Flow - 60-Degrees Rise
|
3.4 gpm
|
5.4 gpm
|
|
Minimum Domestic Hot Water Flow
|
N/A
|
|
Gas Connection
|
3/4 Inch
|
|
Hot/Cold Water Connections
|
3/4 Inch
|
|
Dimensions
|
H 36" by W 19" by D 16"
|
|
Weight
|
132 Pounds
|
146 Pounds
|
|
Voltage
|
120 volts
|
Please Note:
The Massachusetts approval code is 03-05070014.
The Massachusetts MEA numbers are: BMS - G3 - 1003 - 46
The New York MEA numbers are: BMS - 389 - 99 - M
This Gas boiler is not approved in Michigan
|