Buy Energy Efficient Environmentally Conscious Products from HouseNeeds.Com! Solar, Gas Tankless Water Heater, Boilers, Ventilation and more!
Cart (0)     Search   Customer Info   Email Us

Return to Hydronic Gas Boiler Main Page

  Radiant Heat
  PEX Tubing
  Gas Space Heaters
  Electric Heaters
  Boilers
  Heating Supplies
  HVAC
  Radiators
  Solar
  Fan Convectors
  Unit Heaters
  Plumbing Supplies
  Water Heaters
  House Fans
  Water Filtration
  Bath & Kitchen
  Vent Pipe
  Gas Fireplace
  Wood Stoves
  Misc
  Save Energy

  Clearance Items
  Products on Sale
  Whats New?



Oil Prices Getting you down? Cold Showers? High Gas Prices? Click Here to see money saving ideas and products



HACKER SAFE certified sites prevent over 99.9% of hacker crime.

A2723
Houseneeds.com    Home / All Hydronic Boilers / Gas Boilers / JJM Boiler Works Condensate Boiler Neutralizing Tubes Buy

JJM Boiler Works Condensate Boiler Neutralizing Tubes Buy Page

Condensate Neutralizing Tubes

Click Image for more Info (If Available)
Description Price Change quantity in your Shopping Cart. You can always remove items later.
JJM Condensate Boiler Neutralizing Tubes - JM-2
Click here for more info on JJM Boiler Works - JM-2 PH Neutralizer Kit - 150 MBH - 1.30 GPH - Solid White Tube - JM-2 
Click for More Info
JJM Boiler Works - JM-2 PH Neutralizer Kit - 150 MBH - 1.30 GPH - Solid White Tube - JM-2 $50.75 
Click here for more info on JJM Boiler Works - JM-2 PH Neutralizer Kit - 150 MBH - 1.30 GPH - Clear Tube - JM-2 CLEAR 
Click for More Info
JJM Boiler Works - JM-2 PH Neutralizer Kit - 150 MBH - 1.30 GPH - Clear Tube - JM-2 CLEAR $65.75 
Item Description --> JJM Boiler Works - JM-2 PH Neutralizer ReFill Kit - JM-2R  JJM Boiler Works - JM-2 PH Neutralizer ReFill Kit - JM-2R $18.75 
JJM Condensate Boiler Neutralizing Tubes - JM-3
Click here for more info on JJM Boiler Works - JM-3 PH Neutralizer Kit - 300 MBH - 3.45 GPH - Solid White Tube - JM-3  
Click for More Info
JJM Boiler Works - JM-3 PH Neutralizer Kit - 300 MBH - 3.45 GPH - Solid White Tube - JM-3 $53.75 
Click here for more info on JJM Boiler Works - JM-3 PH Neutralizer Kit - 300 MBH - 3.45 GPH - Clear Tube - JM-3 CLEAR 
Click for More Info
JJM Boiler Works - JM-3 PH Neutralizer Kit - 300 MBH - 3.45 GPH - Clear Tube - JM-3 CLEAR $68.75 
Item Description --> JJM Boiler Works - JM-3 PH Neutralizer ReFill Kit - JM-3R  JJM Boiler Works - JM-3 PH Neutralizer ReFill Kit - JM-3R $19.75 


JJM Boiler Works Condensate Boiler Neutralizing Tubes

JJM Boiler Works Condensate Boiler Neutralizing Tubes - JM-2 Solid
JJM Boiler Works Condensate Neutralizing Tubes - JM-2 / JM-3 Solid
The pH measurement of a fluid is an indicator of the acidity or alkalinity. Neutral fluids have pH of 7.0. Acid fluids have pH below 7. And alkaline fluids have pH above 7 (up to 14). The pH can be easily measured using litmus paper.

Condensate pH from condensing boilers and furnaces is acidic. The condensate pH needs to be increased (made less acidic) to prevent possible damage to cast iron soil pipe, ABS pipe, septic tanks, plants, wastewater treatment plants and other materials handling waste water.


JM-series condensate neutralizing tubes increase pH and reduce acidity. Each increase of 1.0 in pH is a 10-times decrease in acidity. The pH of condensate is increased by approximately 1.0 to 3.0 after passing through NB neutralizing tanks. (This is a reduction in acid concentration of from 10 to 1000 times.)
JJM Boiler Works Condensate Neutralizing Tube - JM-2
  • MBH - 150
  • Size - length 10 1/2" x width 2 3/4" x height 3 1/2"
  • Inlet/Outlet Connections - 3/4" hose barb x 1/2" NPT or 3/4" PVC x 1/2" NPT (both supplied)
JJM Boiler Works Condensate Neutralizing Tube - JM-3
  • MBH - 300
  • Size - length 19 1/2" x width 2 3/4" x height 3 1/2"
  • Inlet/Outlet Connections - 3/4" hose barb x 1/2" NPT or 3/4" PVC x 1/2" NPT (both supplied)


Recharge tubes regularly. Tubes should be recharged when pH level moves below 6. The pH should be checked regularly (at least twice during the first year of operation) to determine the required recharging schedule.
This may require recharging as often as twice per year for high-usage systems, such as boiler systems equipped with indirect water heaters.
Boiler/furnace applications for space heating only (no DHW) may require recharging only once per year.

Click here to view PDF Manuals, PDF Documents, PDF Specifications on this product JJM Boiler Works Condensate Boiler Neutralizing Tubes PDF Manuals and Brochures - Click Here

Our Return Policy      Our Shipping Policy


Return to Hydronic Gas Boiler Main Page
Thanks for visiting Houseneeds.Com!
home  •   Shopping Cart  •   products  •   sale items  •   contact us  •   search  •   Help  •   Video Library

Solar Heating - Solar Pumps, Solar Controls and more! Solar Panels for use on domestic hot water or pex radiant heating systems. Gas Tankless Water Heaters! Bosch Instant Hot Water Heater for single and multi use. Takagi Water Heaters! PEX Tubing - PEX Radiant Heat! PEX Underfloor heating. Efficient and Warm. PEX tube in 3/8 to 1 inch sizes. Tamarack Whole House Fans, Attic Fans, Solar Attic Fan, Bath Fans, HEPA Filters, Fantech Energy Recovery Ventilators Hydronic Radiators. Myson Radiators, Myson Fan Convectors, Myson Toe Kick Heaters. Housepex and Houseneeds Classic Radiators. Hydronic Heating - Pumps, Controls, Valves and more. Taco Pumps, Taco Zone Valves, Honeywell Controls, Watts, Azel, Taco Mixing Valves, Cash Acme, Caleffi and more. Fantech Bath Fans, Fantech Kitchen Fans, Fantech HEPA Filters, Fantech Air to Air Handlers!
Solar Heating Gas Tankless Water Heaters
Electric Water Heaters
Radiant PEX Tubing Whole House Fans Hydronic Radiators Heating Supplies Bath and Kitchen Fans


We accept Visa, MasterCard, American Express and Discover Credit Cards.         See our Personal Twitter Houseneeds.com Account     See our Facebook Houseneeds.com Account     See our Houseneeds.com Blog
Copyright © 2000-2013  HouseNeeds Inc.  •  4805 Main Street  •  Waitsfield, Vermont  •  05673  •  1.802.583.2726