Model
|
OM-180 Oil Fired Heater
|
|
Ignition:
|
High Voltage Discharge Spark
|
|
Fuel Type:
|
ASTM D3699 1-K Kerosene No. 1 & ASTM D396 No. 2 Fuel Oil (Typical Home Heating Oil)
|
|
Heat Rating:
|
Input 148,000 BTU/h
|
|
Fuel Consumption:
|
1.05 gal./h
|
|
Min./Max. Hot Water Temperature:
|
68°F / 95°F / 122°F / 158°F / 176°F (approximately)
|
|
Water Flow Rate - Temperature Rise:
|
6.2 gal./min. (40°F rise)
5.0 gal./min. - (50°F rise)
4.1 gal./min. - (60°F rise)
3.5 gal./min. - (70°F rise)
3.1 gal./min. - (80°F rise)
|
|
Capacity of Heat Exchanger:
|
5.10 gal.
|
|
Fuel System:
|
Tank (1)
|
|
Dimensions (W x H x D):
|
12-5/8" by 27-3/4" by 22-1/2"
|
|
Weight:
|
81 lbs - empty
|
|
Temperature Differential Settings:
|
3.6°F, 18°F, 36°F (3 settings by selector switch)
|
|
Vent Pipe Hole:
|
4-3/4" diameter
|
|
Max. Length of Vent Pipe:
|
10 feet with 3 bends or less
|
|
Max. Length of Chimney:
|
26 feet
|
|
Electric Rating:
|
120 Volts AC, 60 Hz
Ignition - 110W
Burning - 98W
|
|
Required Accessories:
|
In-line fuel filter
Temp. & Pressure Relief Valve
(When using the OM-180 as a Hydronic Heating Boiler then a
30 PSI Pressure Relief Valve is required)
Flue pipe installation kit or chimney adapter kit
|
|
Warranty:
|
3 Years - Burner Top & Heat Exchanger
1 Year - Parts
|
|
Exhaust Air Temperature:
|
Less than 500°F
|
|
Safety Devices:
|
Over-heat protector
Ignition safety device
Empty burning protective device
Heat exchanger bi-metal switch
Temperature fuse, Fusible link valve
|