Cart (0) Search Customer Info Email Us |
Home /
All Hydronic Boilers /
All Gas Boilers /
All Electric Boilers /
All Wood Boilers /
All Oil Boilers
|
|
Hot Water Boiler with Primary Secondary Hydronic Heating with 5 Zones (High and Low Temperature) and Indirect Domestic Hot Water Tank
Return to Learning Center Main Page |
|
This is an example of how to use a Gas Boiler to produce different water temperatures for 5 zones
(High / Low Temperatures) plus a zone for the Indirect Hot Water Tank.
You will notice that in this example there are 3 possible temperatures for the heating zones. There are 3 zones for high temperature that can feed radiators or baseboard convectors at whatever the boiler water temperatures is set to. There are 2 zones for a set temperature that could be used for pex radiant heat zones at different water temperatures. This is only an example. Actual layouts vary from job to job. |
|
|
Return to Learning Center Main Page |
|