Fantech Heat Recovery Ventilator - SHR 2004 Buy Page
Fantech Heat Recovery Ventilators for up to 5000 Square Feet
|
Fantech Heat Recovery Ventilator SHR 2004
Fantech Heat Recovery Ventilator SHR-2004 is a complete whole house ventilation system
that incorporates a supply motor and an exhaust motor in one unit. Fantech SHR-2004 is designed to
bring a continuous supply of fresh air into the home while exhausting an equal amount
of contaminated air. HRVs use what is known as a "sensible" heat recovery core. The
special aluminum core transfers heat from the exhaust air stream to the incoming air stream.
Fresh incoming air is tempered by the heat that is transferred from the outgoing air so you
save on energy costs. With the Three speed fan.
The Fantech Heat Recovery Ventilator SHR 2004 is designed for houses up to 5,000 Square feet.
HRVs are designed for colder areas of the country that have longer heating seasons as well
as drier desert areas of the South.
|
Fantech SHR 2004
|
Fantech Heat Recovery Ventilator SHR 2004 Features
- Three speed Fan
- Continuous Exhaust
- 6" Side Ports
- 60-200 CFM (28-94 L/s) at 0.4" w.g.
- Effectiveness (ASE) at 32° F - 77%
- Powder coated 24-gauge galvanized steel cabinets
- Fully insulated with 1" aluminum foil-face high density foam
- German manufactured motors with backward incline impellers
- Includes easy-mount wall bracket
- Aluminum cores
- 7 year limited motor warranty
- Lifetime limited warranty on Aluminum cores
- 5 year limited warranty on component parts
- 35 lbs
- Size: 27 7/8" L by 17 3/8" W by x 20 1/2" H
|
Fantech SHR 2004 Optional Controls
- EDF 1 – On/Off, Low, High Speed Operation and 20 min. On/40 min. Off Cycle Timer
- RTS 3 – Intermittent Bathroom Timer with Settings for 20/40/60 Minutes of High Speed Boost
- EDF 5 – Digital multi-function wall control with recirculation
- EDF 2 – Digital multi-function wall control
- MDEH 2 – Mechanical low voltage dehumidistat with On/Off switch
- MDEH 1 – Mechanical low voltage dehumidistat
- RTS 2 – 15 Minute pushbutton timer
- AQS 1 – Air quality sensor
Note: When installing ERVs (in ERV areas according to the map), and the outdoor temperature
falls below 23°F (-5°C) for more than 2 consecutive days, it is recommended that a defrost option be
installed on the equipment.