Takagi T-KD20 Water Heater - Installation Info
For more detailed information - please download a T-KD20 installation manual (link at the bottom of this page) Return to T-KD20 Main Page |
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
Connect the 4” Category III vent pipe to the minimum 2” round collar on through the outside wall. This water heater must be vented in accordance with the section on venting of equipment in the latest edition of the National Fuel Gas Code. This is a Category III appliance, and must be vented accordingly. The following are UL listed or CSA certified manufacturer: ProTech Systems FasNSeal Stainless Steel Venting. This unit requires 4” vent pipe. Connect the vent pipe to the unit so that it is sealed airtight. Follow the vent pipe manufacturer’s instructions when installing the vent pipe. Do not common vent this appliance with any other vented appliance. The venting system must not exceed a length of 25 ft. minus 5 ft. for every elbow. Do not use more than 3 elbows. If the horizontal vent run exceeds 5 ft., the following criteria must be observed:
The T-KD20 is direct vent (Sealed Combustion) system that all combustible air supplies from outside building. The T-KD20 must be installed in a location where the proper amount of combustible air will be available to it at all times without obstructions. As combustible air supply pipe can be used suitable 3” pipe such as Galvanized single wall vent pipe, ABS 3”, colligate stainless steel pipe and category III stainless steel pipe supply air pipe.
Please Note: Hot Water Heater Temperature over 125 Degrees F can cause severe burns instantly or death from scalding. Children, disabled and elderly are at the highest risk of being scaled. Feel water temperature before bathing or showering. |
|||||||||||||||||||||||||||||||||
|
For more information download a Takagi T-KD20 installation manual in pdf format. Also see all water heater manuals from this link. Return to T-KD20 Main Page |
|||||||||||||||||||||||||||||||||