Bosch Aquastar 2400E Tankless Water Heater Techs & Specs
|
Bosch AquaStar 2400E - Applications and Sizing
|
BTU Input
|
NG: 35,000 to 175,000
LP: 31,000 to 175,000
|
|
Energy Factor
|
NG: .80
LP: .80
|
|
Thermal Efficiency
|
NG: 87%
LP: 86%
|
|
Ignition
|
Electronic (120V plugs in)
|
|
Minimum Flow Rate (gpm)
|
0.8
|
|
Flow Rates (gpm)
|
6.4 @ 45°F rise
5.2 @ 55°F rise
4.5 @ 65°F rise
3.7 @ 77°F rise
3.2 @ 90°F rise
|
|
Weight
|
47 lbs.
|
|
Dimensions
|
23 1/2" h by 15 3/4" w by 8 1/2" d
|
|
Modulating Gas Valve
|
Yes
|
|
Optional Accessories
|
Horizontal Vent Kit AQ3
Remote Thermostat Control
|
|
Life Expectancy
|
20+ years
|
Model AquaStar Bosch 2400E - Installation Specifications
|
Voltage
|
120 VAC
|
|
Exhaust Vent Size
|
3-inch Stainless Steel Sealed Cat III
|
|
Combustion Air Pipe Size
|
3-inch PVC / Alum. / Galv.
|
|
Vent Options
|
Horizontal or Vertical, Direct Vent Room Sealed Combustion
|
|
Exhaust Vent Termination
|
Horizontal or Vertical
|
|
Min / Max Vent Lengths
|
Minimum length: 3 feet
Maximum length: 26 ft. (8m) with one 90 degree elbow.
Less 2.5 ft. for each additional 90 degree elbow (1.25 ft for each 45 degree elbow)
Max 3 90 degree elbows
Please Note: The use of a 90 degree elbow counts as 2 1/2 feet and
a 45 degree elbow counts a 1 1/4 feet toward the minimun vent lenght.
|
|
Gas Connection
|
3/4 inch Male NPT
|
|
Water Connections
|
3/4 inch Male NPT
|
|
Natural Gas Pressure
|
Min: 5" WC
Max: 14" WC
|
|
Propane (LP) Gas Pressure
|
Min: 11" WC
Max: 14" WC
|
|
Water Pressure
|
Min: 30 PSI
Max: 150 PSI
|
What does Direct Vent or Room sealed mean? The 2400E can be installed in a small space
with the ability to take in air from the outside via a 3 inch intake vent.
The Bosch AquaStar 2400E can be vented vertically or horizontally to the
outside. The 2400E requires a dedicated 3" stainless steel single wall
vent pipe. Other vent types will void the warranty and present a health
hazard. The 2400E also requires an electrical connection for the electronic
ignition.
|
Model AquaStar Bosch 2400E - High Altitude Operation
|
|
Propane or Natural Gas
|
Altitude 0 - 4,000 ft
(0-1,219 m)
|
No modification
|
Altitude 4,000 ft - 7,000 ft
(1,219m-2,134m)
|
CO2 adjustment with flue gas analyzer required
Contact CEC for instructions
|
Altitude above 7,000 ft
(2,134m)
|
Not approved
|
|
For operation at elevations above 2,000 ft (610 m) the equipment
ratings shall be reduced at the rate of 4% for each 1000 feet (305m)
above sea level.
|
|
|