Bosch AquaStar 2400ES - Applications and Sizing
|
BTU Input
|
NG: 19,900 to 175,000
LP: 19,900 to 175,000
|
|
Energy Factor
|
.82
|
|
Thermal Efficiency
|
82%
|
|
Ignition
|
Electronic (120V plugs in)
|
|
Minimum Flow Rate to Activate
|
0.65 GPM
|
|
Flow Rates (gpm)
|
6.4 @ 45°F rise
5.3 @ 55°F rise
4.6 @ 65°F rise
3.8 @ 77°F rise
3.2 @ 90°F rise
|
|
Weight
|
67 lbs.
|
|
Dimensions
|
30 1/2" H by 17.875" W by 11 1/4" D
|
|
Modulating Gas Valve
|
Yes
|
|
Optional Accessories
|
Outdoor Kit (AQOK)
Remote Thermostat (TSTAT2)
|
|
Life Expectancy
|
20+ years
|
Model AquaStar Bosch 2400ES - Installation Specifications
|
Voltage
|
120 VAC
|
|
Exhaust Vent Size
|
3-inch Stainless Steel
|
|
Combustion Air Pipe Size
|
3-inch PVC / Alum. / Galv.
|
|
Vent Termination
|
Horizontal or Vertical
|
|
Min / Max Vent Lengths
|
Minimum length: 3 feet
Maximum length: 26 ft. (8m) with one 90 degree elbow.
Less 2.5 ft. for each additional 90 degree elbow (1.25 ft for each 45 degree elbow)
Max 3 90 degree elbows.
May require an Condensate Drain - see Install Manual
|
|
Gas Connection
|
3/4 inch Male NPT
|
|
Water Connections
|
3/4 inch Male NPT
|
|
Natural Gas Pressure
|
Min: 4" WC
Max: 14" WC
|
|
Propane (LP) Gas Pressure
|
Min: 9" WC
Max: 14" WC
|
|
Water Pressure
|
Min: 30 PSI
Max: 150 PSI
|
Model AquaStar Bosch 2400ES - High Altitude Operation
|
|
Propane or Natural Gas
|
|
Altitude 0 - 2,000 ft
|
No modification
|
Altitude 2,000 ft - 8,000 ft
(For FD Codes higher than 892)
|
CO2 adjustment with flue gas analyzer required
see manual supplied from unit for instructions
|
|
For operation at elevations above 2,000 ft (610 m) the equipment
ratings shall be reduced at the rate of 4% for each 1000 feet (305m)
above sea level.
|
|
|