Model
|
Precision Temp ShowerMate
|
|
Type:
|
Gas instantaneous, power vented. Full gas modulation temperature control.
|
|
Dimensions:
|
11.5" Wide x 13.5" Deep x 14.25" High. Weight: 35 lbs full
|
|
Hook-ups:
|
Electric: 18-2 x 2' lead.
Gas: Brass 3/8" flare inside case, rear accessible.
Water: 1/2" OD copper tubing. Brass compression to 1/2" NPT elbow can be installed or as specified.
|
|
Capacity:
|
55,000 Btu input - 44,000 Btu output at maximum burn at 8.5 WCI manifold pressure.
15,000 Btu input - 10,600 Btu output at low burn at 1.2 WCI manifold pressure.
(88°F temperature rise per gallon per minute continuous flow at high burn).
|
|
Fuel Consumption:
|
2.55 lbs per hour at maximum input. (At 2 GPM of water, 20 lbs of propane will produce over 940 gallons of hot water).
|
|
Mounting:
|
Side mounted keyed bracket. Left or right side mounted.
|
|
Clearances:
|
Zero clearance top (blower), bottom and sides.
2" in back for hook-ups. Enough space in front to remove cover for service.
|
|
Flue:
|
2" power vent with proofing switch. (3" stainless flex duct recommended to the outside and can run up to 25')
|
|
Construction:
|
Modular: Three assemblies; gas, electronics and water.
Burner: High primary air, 12 element, atmospheric type. Aluminized steel body with stainless flame strips.
Heat exchanger: Copper fin tube type with wrap for cooling.
Electronics: Plug in, potted, works-in-a-drawer.
Case and flue assembly are stainless steel.
|
|
Fuel:
|
Propane at 11 WCI
|
|
Power:
|
12 VDC at 4 amps while running, 40 milli-amps in standby. # 12 power line recommended.
|
|
Water Temperature:
|
Factory set at 115°F. Can be field adjusted 90° to 135°F.
|
|
Mounting:
|
Mounting flanges included. Must be mounted in accordance with any applicable Coast Guard and ABYC recommendations.
|
|
Safety Features:
|
- The Shower-Mate is pilotless. There is no flame unless water flow is sensed.
- Flame rectification: Gas valve shuts off in .8 of a second if there is a flame outage.
- Redundant gas solenoid.
- Electronic high temperature shut-off (two).
- ECO high temperature shut off at 165°F with manual reset.
- Pressure relief valve at 100 PSI.
- Power vent must proof fluing before gas valve opens.
|
|
Due to continuous product improvement PrecisionTemp reserves the right to change
specifications at any time.
|