PowerStar AE 115 / AE 125 Techs and Specs
|
PowerStar Specifications
|
Model
|
45°F Rise
|
50°F Rise
|
60°F Rise
|
70°F Rise
|
80°F Rise
|
|
AE 115
|
2.6 gpm
|
2.3 gpm
|
1.9 gpm
|
1.7 gpm
|
1.5 gpm
|
|
AE 125
|
4.0 gpm
|
3.7 gpm
|
3.0 gpm
|
2.6 gpm
|
2.3 gpm
|
|
*Flow rates calculated at 240 volts, lower voltage input will reduce temperature
rise. For optimal performance of both units, use one major water source at a
time. Note: AE 115 will have a slow bathtub or washing machine fill time.
|
|
PowerStar Sizing Chart
|
Model
|
Capacity
|
|
AE 115
|
Provides 2.0 gallons per minute for water usage at 115°F: sink, dishwasher (not simultaneously)
Provides 2.3 gallons per minute for water usage at 105°F: shower, laundry, bathtub
(bathtub fills in about 13 minutes)
|
|
AE 125
|
Provides 3.0 gallons per minute for water usage at 115°F: 2 sinks at once, dishwasher.
Provides 3.7 gallons per minute for water usage at 105°F: 2 sinks at once or 1 shower,
(bathtub fills in about 7 minutes).
|
AE115 is not recommended in climates where average annual ground water temperature is
less than 60°F.
|
|
PowerStar Specsfications AE115 & AE125
|
Model
|
Volts
|
Kilowatts
|
Amps
|
Wire Size
|
Weight
|
Dimensions
|
|
AE 115
|
240v 208v
|
19 kw 14.25kw
|
80 (2 x 40a) 69 (2 x 40a)
|
8 ga. (4 connectors) 8 ga. (4 connectors)
Minimum 150 Amp Service
|
23 lbs.
|
15 1/2" x 15 1/4" x 4 1/2"
|
|
AE 125
|
240v 208v
|
28 kw 21kw
|
120 (3 x 40a) 101 (3 x 40a)
|
8 ga. (6 connectors) 8 ga. (6 connectors) Minimum 200 Amp Service
|
25 lbs.
|
15 1/2" x 15 1/4" x 4 1/2"
|
|
PowerStar AE 115 and AE 125 PDF Manuals and Brochures - Click Here
Return to PowerStar Water Heater Main Page
|